Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
J Adhes Dent ; 24(1): 39-48, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35227045

RESUMEN

PURPOSE: To experimentally assess the effect of regenerative heat treatment (HT) on yttria-stabilized tetragonal zirconia polycrystalline ceramic (Y-TZP) to guarantee veneer adhesion strength. MATERIALS AND METHODS: One surface of bar-shaped Y-TZP specimens was ground (G) with a diamond stone, while the control samples (C) were not. Groups C900 and G900 were submitted to HT at 900°C for 60 min, whereas groups C1000 and G1000 were submitted to HT at 1000°C for 30 min. The treated surfaces were characterized by x-ray diffractometry (XRD), scanning electron microscopy (SEM), and optical and mechanical profilometry. The energy release rate through interface fracture was determined by a four-point bending test on notched Y-TZP veneered specimens. XRD was refined by the Rietveld method, mean roughness (Ra) and energy release rate were submitted to two-way ANOVA (a = 0.05), and the images were analyzed descriptively. RESULTS: The monoclinic phase (vol%), means of Ra (µm), and the energy release rate (J/m2) were, respectively: C = 1.2/0.17/6.8, C900 = 0.0/0.18/6.6, C1000 = 0.0/0.18/7.6, G = 2.6/1.16/8.3, G900 = 0.0/1.07/8.0, and G1000 = 0.0/1.01/5.7. The surface fraction of monoclinic zirconia increased by grinding and decreased by HT. Ra also increased after grinding (p < 0.005) but remained unaltered after HT (p = 0.22). Increased irregularity was observed in the G groups and a subtle smoothing of the surface after HT. After the fracture of the bilayers, a residual amount of porcelain could be seen on the zirconia surface in all groups. The energy release rate was statistically equal among all groups (p > 0.05). CONCLUSION: Heat treatment after grinding completely restored the tetragonal phase of zirconia without altering the energy release rate during interfacial fracture.


Asunto(s)
Porcelana Dental , Calor , Cerámica/química , Porcelana Dental/química , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Itrio/química , Circonio/química
2.
J Mater Sci Mater Med ; 32(9): 110, 2021 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-34453617

RESUMEN

This study aimed to evaluate the effect of grinding on some surface properties of two lithium disilicate-based glass-ceramics, one experimental new product denominated LaMaV Press (UFSCar-Brazil) and another commercial known as IPS e-max Press (Ivoclar), in the context of simulated clinical adjustment. Discs (N = 24, 12 mm in diameter) were separated into four groups: LaMaV Press with no grinding (E), LaMaV Press after grinding (EG), IPS e-max Press with no grinding (C), and IPS e-max Press after grinding (CG). A 0.1-mm deep grinding was carried out on EG and CG samples (final thickness of 1.4 mm) using a diamond stone in a low-speed device. The E and C samples had the same thickness. The effect of grinding on the sample surfaces was evaluated by X-ray diffraction, mechanical and optical profilometry, scanning electron microscopy, goniometry, and Vickers hardness. The mean roughness (Ra) was evaluated by Kruskal-Wallis and Student-Newman-Keuls statistics. The surface energy (SE) by the sessile drop method and Vickers hardness (VH) were analyzed using two-way ANOVA. The Ra medians were E = 1.69 µm, EG = 1.57 µm, C = 1.45 µm, and CG = 1.13 µm with p = 0.0284. The SE and VH were similar for all materials and treatments. Grinding smoothed the surfaces and did not significantly alter the hardness and surface energy of both LaMaV Press and IPS e-max Press. These glass-ceramics presented similar surface properties, and clinical adjustments can be implemented without loss of performance of both materials. A grinding standardization device developed that allowed to control the amount of grinding, the speed of rotation speed and the force exerted on the samples.


Asunto(s)
Cerámica/química , Porcelana Dental/química , Cerámica/síntesis química , Diseño Asistido por Computadora , Porcelana Dental/síntesis química , Diamante/química , Dureza , Humanos , Ensayo de Materiales , Fenómenos Mecánicos , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Difracción de Rayos X
3.
Rev. odontol. UNESP (Online) ; 46(5): 284-291, Sept.-Oct. 2017. tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-902667

RESUMEN

Objective: Due increased number of elders living in long-term care institutions, actions designs to improve their oral health are essential. Thus, the aim of this study was to evaluate the impact of an educational program for the caregivers through the assessment of the oral hygiene of institutionalized elders. Material and method: The education program consisted in lectures to caregivers about oral health that were performed once a month. The subjects were 40 functionally dependent institutionalized elders and 14 caregivers. Hygiene habits, plaque index, and tongue coating/discoloration of the elders were measured before the educational program (baseline- T0) and after 6 (T1), 12 (T2), 18 (T3) and 24 months (T4). Caregivers answered questions about their knowledge, doubts and implementation of dental care (T0 to T4). Result: After analyzing the data (Friedman, Chi-square and Spearman α = 0.05), a gradual improvement in the oral hygiene of the subjects was observed, with an increased frequency of brushing (p=0.0005), a change in the brush type (p=0.0065) and a reduction in the plaque index (p<0.05) and tongue coating (p<0.05). Caregivers showed a marked improvement in their dental care knowledge. Conclusion: It was concluded that the educational program for caregivers had a positive impact in the oral health of institutionalized elderly observed by the increased in the effectiveness of oral hygiene parameters such as plaque index and tongue coating, contributing to the knowledge gain in hygiene by caregivers.


Objetivo: Devido ao aumento do número de idosos que vivem em instituições de longa permanência são essenciais projetos de ações para melhorar a saúde bucal. Assim, o objetivo deste estudo foi avaliar o impacto de um programa educacional para os cuidadores de idosos institucionalizados por meio da avaliação da higiene bucal. Material e método: O programa de educação consistiu em palestras para cuidadores sobre saúde bucal que foram realizadas uma vez por mês. Foram avaliados 40 idosos institucionalizados dependentes funcionalmente e 14 cuidadores. Os hábitos de higiene, o índice de placa e o revestimento/descoloração da língua dos idosos foram avaliados antes do programa educacional (T0) e após 6 (T1), 12 (T2), 18 (T3) e 24 meses (T4). Os cuidadores responderam perguntas sobre seus conhecimentos, suas dúvidas e sobre a implementação de cuidados bucais (T0 a T4). Resultado: Após análise dos dados (Friedman, Qui-quadrado e Spearman, α = 0,05), observou-se melhora gradual na higiene oral dos idosos, com maior freqüência de escovação (p = 0,0005), alteração do tipo de escova (p = 0,0065) e redução do índice de placa (p <0,05) e revestimento da língua (p <0,05). Os cuidadores mostraram uma melhoria acentuada no seu conhecimento sobre saúde bucal. Conclusão: Concluiu-se que o programa educacional para cuidadores teve um impacto positivo na saúde bucal dos idosos institucionalizados observado pelo aumento na eficácia dos parâmetros de higiene bucal, como índice de placa e revestimento da língua, contribuindo para o ganho de conhecimento em higiene pelos cuidadores.


Asunto(s)
Higiene Bucal , Lengua , Cepillado Dental , Anciano , Cuidadores , Hogares para Ancianos , Distribución de Chi-Cuadrado , Cuidado Dental para Ancianos , Estadísticas no Paramétricas , Placa Dental , Educación
4.
J Oral Implantol ; 43(4): 297-301, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28628350

RESUMEN

The lack of compatible prosthetic components can be a complication during oral rehabilitation using outdated implants. The aim of the present clinical report was to describe an alternative technique for the fabrication of a maxillary implant-supported overdenture in a patient with 20-year-old dental implants using castable spherical patterns and ball attachments. The patient had been wearing a relined bar/clip overdenture in the mandible on 4 external-hexagon dental implants and a relined complete denture in the maxilla on 4 internal-hexagon implants due to abutment screw fracture inside of the implants, losing the attachment system. The remaining maxillary dental implants did not possess attachments compatible with current systems due to configuration changes by the manufacturer in the dental implant's platform and the components over time. Therefore, castable spherical patterns and cast ball attachments were used to fabricate a maxillary implant-supported overdenture. The mandible rehabilitation was performed using 4 osseointegrated dental implants with a fixed implant-supported prosthesis. The use of cast ball attachments on the maxillary dental implants avoided invasive procedures on the remaining implants. Considering the lack of available compatible prosthetic components for the osseointegrated implants, this technique was considered a viable and satisfactory treatment option.


Asunto(s)
Prótesis Dental de Soporte Implantado/instrumentación , Prótesis Dental de Soporte Implantado/métodos , Retención de Dentadura/métodos , Prótesis de Recubrimiento , Arcada Edéntula/cirugía , Diseño de Dentadura , Humanos , Mandíbula/cirugía , Maxilar/cirugía
5.
Dent Mater J ; 36(4): 447-453, 2017 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-28420828

RESUMEN

This study evaluated microstructural and crystallographic phase changes after grinding (G) and regeneration firing/anneling (R) of Y-TZP ceramics. Thirty five bars (LavaTM and Ice Zirkon) were divided: Y-TZP pre-sintered, control (C), regeneration firing (R), dry grinding (DG), dry grinding+regeneration firing (DGR), wet grinding (WG) and wet grinding+regeneration firing (WGR). Grinding was conducted using a diamond bur and annealing at 1,000°C. The microstructure was analyzed by SEM and the crystalline phases by X-ray diffraction (XRD). XRD showed that pre-sintered specimens contained tetragonal and monoclinic phases, while groups C and R showed tetragonal, cubic and monoclinic phases. After grinding, the cubic phase was eliminated in all groups. Annealing (DGR and WGR) resulted in only tetragonal phase. SEM showed semi-circular cracks after grinding and homogenization of particles after annealing. After grinding, surfaces show tetragonal and monoclinic phases and R can be assumed to be necessary prior to porcelain layering when grinding is performed.


Asunto(s)
Porcelana Dental , Circonio , Ensayo de Materiales , Regeneración , Propiedades de Superficie , Difracción de Rayos X , Itrio
6.
J Prosthet Dent ; 117(1): 158-163, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27475916

RESUMEN

STATEMENT OF PROBLEM: The changes that occur after brushing yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) are unknown. These changes may favor the retention of microorganisms and chemisorption of water, impairing its longevity. OBJECTIVE: The purpose of this in vitro study was to evaluate the effects of a whitening dentifrice on Y-TZP surfaces after simulating 10 years of brushing. MATERIAL AND METHODS: Seventy-two bar-shaped specimens (20×4×1.2 mm) were divided into 4 groups: storage in distilled water (SW, control), brushing with distilled water (BW), brushing with dentifrice (BD), and brushing with whitening dentifrice (BWD). Brushing was conducted using a linear brushing machine (878400 cycles, 0.98 N, soft toothbrush). The mean roughness (Ra) was analyzed with a profilometer and the superficial topography with scanning electron microscopy (SEM) at baseline and after treatment. Crystalline phases were characterized using x-ray diffraction. Baseline and posttreatment Ra were analyzed using the 1-way ANOVA and Tukey HSD multiple comparison test; the paired t test was used for intragroup comparison (all α=.05). RESULTS: The Ra (µm) means (before/after treatment) were SW 0.28/0.28; BW 0.32/0.31; BD 0.28/0.36; BWD 0.30/0.20. No statistically significant difference was found for Ra at baseline (P=.108) than for posttreatment results (P<.001); the BD group had higher Ra values when compared with baseline (P=.019); the BWD group had the lowest values (P<.001). The BD surfaces showed pronounced scratches and detachment of the surface, while BWD showed smoother surfaces; similar crystallographic results among groups were observed. CONCLUSIONS: Brushing Y-TZP with conventional dentifrice increased roughness, while brushing with whitening dentifrice reduced roughness. Neither dentifrice changed the crystallographic phases after brushing.


Asunto(s)
Dentífricos/efectos adversos , Cepillado Dental/efectos adversos , Itrio , Circonio , Técnicas In Vitro , Propiedades de Superficie , Itrio/normas , Circonio/normas
7.
Braz Dent J ; 27(4): 468-75, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27652713

RESUMEN

This study evaluated the effect of grinding protocols and resintering on flexural fatigue limit and surface characterization of LavaTM Y-TZP. Bar-shaped specimens (20×4.0×1.2 mm, n=40; 20×4.0×1.5 mm, n=80) were obtained. Half of the thinner specimens (1.2 mm) constituted the as-sintered group (AS), while the thicker ones (1.5 mm) were ground with diamond burs under irrigation (WG) or not (G). The other half of thinner and half of ground specimens were resintered (1000 ºC, 30 min), forming the groups ASR, WGR and GR. Fatigue limit (500,000 cycles, 10 Hz) was evaluated by staircase method in a 4-point flexural fixture. Data were analyzed by 2-way ANOVA and Tukey's test (α=0.05). Surface topography (n=3) and fracture area (n=3) were evaluated by SEM. X-ray diffraction data (n=1) was analyzed by Rietveld refinement. ANOVA revealed significant differences (p<0.001) for the grinding protocol, resintering and their interaction. Grinding increased the fatigue limit of non-resintered groups. There was no significant difference among the resintered groups. Resintering significantly increased the fatigue limit of the AS group only. Both protocols created evident grooves on zirconia surface. The failures initiated at the tensile side of all specimens. The percentages (wt%) of monoclinic phase were AS (8.6), ASR (1.2), G (1.8), GR (0.0), WG (8.2), WGR (0.0) before, and AS (7.4), ASR (6.5), G (3.2), GR (0.2), WG (4.6), WGR (1.1) after cyclic loading. Grinding increased the fatigue limit of non-resintered Y-TZP and formed evident grooves on its surface. Resintering provided significant increase in the fatigue limit of as-sintered specimens. In general, grinding and resintering decreased or zeroed the monoclinic phase.


Asunto(s)
Cerámica , Ensayo de Materiales , Itrio/química , Circonio/química
8.
Braz. dent. j ; 27(4): 468-475, July-Aug. 2016. tab, graf
Artículo en Inglés | LILACS | ID: lil-794618

RESUMEN

Abstract This study evaluated the effect of grinding protocols and resintering on flexural fatigue limit and surface characterization of LavaTM Y-TZP. Bar-shaped specimens (20×4.0×1.2 mm, n=40; 20×4.0×1.5 mm, n=80) were obtained. Half of the thinner specimens (1.2 mm) constituted the as-sintered group (AS), while the thicker ones (1.5 mm) were ground with diamond burs under irrigation (WG) or not (G). The other half of thinner and half of ground specimens were resintered (1000 ºC, 30 min), forming the groups ASR, WGR and GR. Fatigue limit (500,000 cycles, 10 Hz) was evaluated by staircase method in a 4-point flexural fixture. Data were analyzed by 2-way ANOVA and Tukey's test (α=0.05). Surface topography (n=3) and fracture area (n=3) were evaluated by SEM. X-ray diffraction data (n=1) was analyzed by Rietveld refinement. ANOVA revealed significant differences (p<0.001) for the grinding protocol, resintering and their interaction. Grinding increased the fatigue limit of non-resintered groups. There was no significant difference among the resintered groups. Resintering significantly increased the fatigue limit of the AS group only. Both protocols created evident grooves on zirconia surface. The failures initiated at the tensile side of all specimens. The percentages (wt%) of monoclinic phase were AS (8.6), ASR (1.2), G (1.8), GR (0.0), WG (8.2), WGR (0.0) before, and AS (7.4), ASR (6.5), G (3.2), GR (0.2), WG (4.6), WGR (1.1) after cyclic loading. Grinding increased the fatigue limit of non-resintered Y-TZP and formed evident grooves on its surface. Resintering provided significant increase in the fatigue limit of as-sintered specimens. In general, grinding and resintering decreased or zeroed the monoclinic phase.


Resumo Este estudo avaliou o efeito de protocolos de desgaste e ressinterização no limite de fadiga flexural e na caracterização da superfície da zircônia LavaTM. Corpos-de-prova em forma de barra (20×4,0×1,2 mm, n=40; 20×4,0×1,5 mm, n=80) foram obtidos. Metade das barras com menor altura (1,2 mm) constituiu o grupo controle (AS), enquanto as de maior altura (1,5 mm) foram desgastadas com fresas diamantadas com (WG) ou sem (G) irrigação. A outra metade dos corpos-de-prova de menor altura e metade dos desgastados foram ressinterizadas (1000 °C, 30 min), obtendo-se os grupos ASR, WGR e GR. O limite de fadiga (500.000 ciclos, 10 Hz) foi avaliado pelo método de escada em dispositivo de flexão em 4 pontos. Os dados foram analisados pelos testes ANOVA a dois fatores e Tukey (α=0,05). A topografia de superfície (n=3) e área de fratura (n=3) foram avaliadas por MEV. Os dados de difração de raios-X (n=1) foram analisados pelo refinamento de Rietveld. ANOVA revelou diferenças significantes (p<0,001) para desgaste, ressinterização e interação entre os fatores. O desgaste aumentou o limite de fadiga para os grupos não ressinterizados. Não houve diferença significante entre os grupos ressinterizados. A ressinterização aumentou o limite de fadiga somente para o grupo AS. Ambos os protocolos criaram riscos evidentes na superfície da zircônia. As falhas iniciaram sempre no lado de tração. A porcentagem de fase monoclínica foi: AS (8.6), ASR (1.2), G (1.8), GR (0.0), WG (8.2), WGR (0.0) antes e AS (7.4), ASR (6.5), G (3.2), GR (0.2), WG (4.6), WGR (1.1) após a ciclagem. O desgaste aumentou o limite de fadiga da zircônia não ressinterizada e formou ranhuras evidentes na sua superfície. A ressinterização promoveu aumento significativo no limite de fadiga somente para o grupo controle. Em geral, o desgaste e a ressinterização diminuíram ou anularam o conteúdo de fase monoclínica.


Asunto(s)
Cerámica , Ensayo de Materiales , Itrio/química , Circonio/química
9.
RGO (Porto Alegre) ; 63(3): 337-342, July-Sept. 2015. graf
Artículo en Inglés | LILACS | ID: lil-765061

RESUMEN

Cerebral palsy is a disorder caused by central nervous system injuries that can occur during the prenatal, perinatal, or postnatal periods. It is characterized by multiple abnormalities, including impairment of speech, body and motor coordination, balance, intelligence, mastication, and swallowing. Due to abnormal movements of the facial muscles, compounded by impairment of the self-cleansing mechanism of the oral cavity, patients with this condition can develop oral diseases such as caries, periodontal disease, and tooth loss. The aim of this paper is to report a case of a patient with cerebral palsy who presented with absence of the maxillary central incisors, removable prosthesis wear, and oral candidiasis. Impressions of the upper and lower arches and periapical radiographs were obtained. The lateral incisors were found to exhibit root resorption, which contraindicated their use as abutment teeth for fixed prosthodontics. In view of the patient's socioeconomic status and cerebral palsy-related limitations, a resin-bonded fixed partial denture was fabricated and nystatin solution was used for treatment of oral candidiasis. The patient had an esthetically and functionally adequate outcome.


A paralisia cerebral é uma anormalidade causada por lesões no sistema nervoso central que podem ocorrer durante o período pré, peri ou pós-natal. É caracterizada por alterações múltiplas como o comprometimento da fala, da coordenação motora e corporal, do equilíbrio, do intelecto e da mastigação e deglutição. Devido aos movimentos anormais da musculatura facial, juntamente com o comprometimento da função de autolimpeza, o paciente pode apresentar quadros de patologia bucal como a cárie, a doença periodontal e a perda dental. O objetivo deste trabalho foi relatar o caso clínico de um paciente portador de paralisia cerebral com ausência dos incisivos centrais superiores, portador de prótese removível e com um quadro de candidose bucal. Foi realizada a moldagem dos arcos superior e inferior e as radiografias periapicais. Pôde-se observar que os incisivos laterais apresentavam reabsorção radicular, o que contra indicava a sua utilização como pilares para prótese fixa. Devido às condições sócio-econômicas e limitações relacionadas a paralisia cerebral, foi confeccionada uma prótese adesiva e, para a candidose bucal foi instituído o tratamento com solução de Nistatina. O resultado do tratamento foi estética e funcionalmente adequado para o paciente.

10.
Case Rep Dent ; 2015: 102189, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25628899

RESUMEN

The oral rehabilitation of edentulous patients with immediate loading has become a safe procedure with high predictability. The success is related to immediate fabrication of a passive fit framework to attach the implants. Based on these considerations, this case report shows an alternative technique for mandibular rehabilitation using implants immediately loaded, where the framework was fabricated using cylinders with internal reinforcement and precast pieces, electrowelding, and conventional welding providing esthetics and function to the patient in a short period of time.

11.
Rev. odontol. UNESP (Online) ; 43(6): 379-383, Nov-Dec/2014. tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: lil-730690

RESUMEN

Introduction: The Y-TZP zirconia used for prosthetic infrastructure, in some clinical situations, can be exposed to the oral environment. In these situations, a polished surface without changes is extremely important. Objective: The aim of this study was to evaluate the mean roughness (Ra) and Vickers hardness of Y-TZP zirconia (LavaTM) after simulating ten years of brushing. Material and method: Thirty-six Y-TZP bar-shaped specimens (20mm X 4mm X 1.2mm) were divided into three groups: storage in distilled water (DW, n=12, control); brushing with distilled water (BDW, n=12) and brushing with distilled water and fluoride toothpaste (BFT, n=12). Brushing was performed using a brushing machine with a soft-bristled toothbrush, simulating 10 years of brushing (878.400 cycles, 100gf). The mean roughness (Ra in µm)) and Vickers hardness (VHN) of all specimens were measured twice: before and after the experimental treatment, in profilometer and microhardness tester (500gf, 30 seconds), respectively. Data were analyzed using the two-way ANOVA test (α = 0.05). Result: The interaction between groups was not significant for roughness (p = 0.701) nor for hardness (p = 0.928). The final averages for Ra (μm) were equal to: DW - 0.63; BDW - 0.64; and, BFT - 0.68. The final averages for Vickers hardness (VHN) were: DW - 1301.16; BDW - 1316.60; and, BFT - 1299.58. Conclusion: It was concluded that the brushing with distilled or fluoridated toothpaste was not able to change the roughness and hardness of Y-TZP zirconia used in this study. .


Introdução: A zircônia estabilizada por ítria (Y-TZP) utilizada para infraestruturas protéticas pode, em algumas situações clínicas, ficar exposta ao meio bucal, e nessas situações, uma superfície sem alterações e polida é extremamente importante. Objetivo: Assim, este estudo avaliou a rugosidade média (Ra) e a dureza Vickers da zircônia LavaTM após simulação de dez anos de escovação. Material e método: Foram confeccionados 36 espécimes (20mm X 4mm X 1,2mm), divididos em três grupos: armazenamento em água destilada (AD, n=12, controle), escovação com água destilada (EAD, n=12) e escovação com água destilada e dentifrício fluoretado (EDF, n=12). A escovação foi realizada em máquina de escovação simulando 10 anos (878.400 ciclos, lOOgf) com escova dental macia. A rugosidade média (Ra, em µm) e a dureza Vickers (VHN) de todos os corpos-de-prova foram mensuradas em dois momentos: antes e após o tratamento experimental, em rugosímetro e microdurômetro (500gf, 30 segundos), respectivamente. Os dados foram analisados por meio do teste two-way ANOVA (α=0,05). Resultado: A interação entre os grupos não foi significativa tanto para a rugosidade (p=0,701) quanto para a dureza (p=0,928), sendo as médias finais de Ra (µm) iguais a: AD - 0,63; EAD - 0,64 e EDF - 0,68 e as de dureza Vickers (VHN) iguais a: AD - 1301,16; EAD - 1316,60 e EDF - 1299,58. Conclusão: Concluiu-se que o procedimento de escovação com água destilada ou com dentifrício fluoretado não foi capaz de alterar a rugosidade e a dureza da zircônia Y-TZP utilizada neste estudo. .


Asunto(s)
Cepillado Dental , Circonio , Agua Destilada , Cerámica , Análisis de Varianza , Dentífricos , Dureza
12.
J. appl. oral sci ; 22(6): 496-501, Nov-Dec/2014. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: lil-732584

RESUMEN

Favorable results in the use of castor oil polyurethane (COP) as pulp capping, membrane material, sealer, mouthwash and in bone repair, associated with the fact that Ricinus communis is not derived from petroleum and it is abundant in Brazil, encourage researches in the development of luting agents. Objectives This study compared the flexural strength (FS) of a castor oil-containing dental luting agent with a weight percentage of 10% (wt%) of calcium carbonate (COP10) with RelyX ARC (RX) after mechanical cycling (MC) and distilled water storage. Material and Methods Sixty-four specimens (25x2x2 mm) were fabricated and divided into two groups, COP10 and RX (control). Each group was divided into 4 subgroups (n=8) according to the storage time, 24 hours (24 h) or 60 days (60 d), and the performance (MC+FS) or not (only FS) of the mechanical cycling test. The FS (10 kN; 0.5 mm/min) and MC tests (10,000 cycles, 5 Hz, 0.5 mm/min) were carried out using an MTS-810 machine. The data were analyzed using ANOVA (α=0.05). Results The obtained FS (MPa) values were: COP10 24h- 19.04±2.41; COP10 60d- 17.92±3.54; RX 24h- 75.19±3.43; RX 60d- 88.77±6.89. All the RX specimens submitted to MC fractured, while the values for COP10 after MC were as follows: COP10 24h- 17.90±1.87 and COP10 60d- 18.60±1.60. Conclusions A castor oil-containing dental luting agent with a weight percentage of 10% (wt%) of calcium carbonate is resistant to mechanical cycling without decreases in flexural strength. However, mean COP10 showed only about 25% of the RelyX ARC mean flexural strength. .


Asunto(s)
Bisfenol A Glicidil Metacrilato/química , Carbonato de Calcio/química , Aceite de Ricino/química , Cementos Dentales/química , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Poliuretanos/química , Análisis de Varianza , Análisis del Estrés Dental , Inmersión , Ensayo de Materiales , Docilidad , Valores de Referencia , Estrés Mecánico , Factores de Tiempo , Agua/química
13.
J Adhes Dent ; 16(5): 451-8, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25191667

RESUMEN

PURPOSE: To evaluate the effect of grinding and airborne-particle abrasion on the biaxial flexural strength (BFS) and phase transformation of a Y-TZP ceramic, and examine whether sintering the veneering porcelain renders the previous heat treatment recommended by the manufacturer unnecessary. MATERIALS AND METHODS: Lava zirconia specimens (N = 108) were obtained with the following dimensions: 14.0 mm diameter × 1.3 mm thickness (n = 36) and 14.0 mm × 1.6 mm (n = 72). The thicker specimens were ground with diamond burs under irrigation and received (heat-treated groups) or not (non-heat-treated groups) a heat treatment (1000°C for 30 min) prior to the four firing cycles applied to simulate the sintering of the veneering porcelain. All specimens were air abraded as follows (n = 12): 1) 30-µm silica-modified Al2O3particles (Rocatec Soft); 2) 110-µm silica-modified Al2O3particles (Rocatec Plus); and 3) 120-µm Al2O3particles, followed by Rocatec Plus. Three specimens of each group were analyzed by x-ray diffraction (XRD) to assess the monoclinic phase content (%). The BFS test was performed in a mechanical testing machine (Instron 8874). Data (MPa) were analyzed by two-way ANOVA (grinding × airborne-particle abrasion and heat treatment × airborne-particle abrasion) and Tukey's post-hoc test (α = 0.05). The strength reliability was analyzed using the Weibull distribution. RESULTS: Grinding significantly decreased the BFS of the non-heat-treated groups (p < 0.01). Within the ground groups, the previous heat treatment did not influence the BFS (p > 0.05). Air abrasion only influenced the BFS of the ground/heat-treated groups (p < 0.01). For the non-heat-treated groups, the grinding did not decrease the Weibull modulus (m), but it did decrease the characteristic strength (σ0). For Rocatec Soft and 120-µm Al2O3particles + Rocatec Plus, the heat-treated groups presented lower m and higher σ0 than the ground/non-heat-treated groups. The independent variables did not seem to influence phase transformation. Air-abraded surfaces presented higher monoclinic zirconia content than the as-sintered and ground surfaces, which exhibited similar content. CONCLUSION: Even under irrigation, grinding compromised the Y-TZP ceramic strength. The sintering of the veneering porcelain rendered the previous heat treatment recommended by the manufacturer unnecessary. Airborneparticle abrasion influenced the strength of heat-treated zirconia.


Asunto(s)
Porcelana Dental/química , Itrio/química , Circonio/química , Óxido de Aluminio/química , Cristalografía , Grabado Dental/métodos , Análisis del Estrés Dental/instrumentación , Coronas con Frente Estético , Diamante/química , Módulo de Elasticidad , Calor , Ensayo de Materiales , Docilidad , Dióxido de Silicio/química , Estrés Mecánico , Propiedades de Superficie , Agua/química , Difracción de Rayos X/métodos
14.
In. Miyashita, Eduardo; Pellizzer, Eduardo Piza; Kimpara, Estevão Tomomitsu. Reabilitação oral contemporânea baseada em evidências científicas. Nova Odessa, Napoleão editora, jun. 2014. p.312-353, ilus. (BR).
Monografía en Portugués | LILACS, BBO - Odontología | ID: lil-715170
15.
J Prosthet Dent ; 112(2): 369-72, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24433838

RESUMEN

Because of the functional and esthetic requirements of patients, different techniques have been proposed to reduce the time between dental implant placement and interim restoration fabrication. This article describes a modified indexing technique by using a surgical template for open-tray impression and definitive cast development during immediate loading procedures. This technique does not use a complete impression of the oral cavity and, therefore, is more comfortable, less time consuming, and less expensive. It also allows the fabrication of interim restorations with the optimal shape for developing an adequate emergence profile.


Asunto(s)
Implantes Dentales , Prótesis Dental de Soporte Implantado , Carga Inmediata del Implante Dental/métodos , Técnica de Colado Dental , Implantación Dental Endoósea/instrumentación , Materiales de Impresión Dental/química , Técnica de Impresión Dental/economía , Técnica de Impresión Dental/instrumentación , Diseño de Prótesis Dental , Restauración Dental Provisional , Humanos , Carga Inmediata del Implante Dental/instrumentación , Modelos Dentales , Polimetil Metacrilato/química , Polivinilos/química , Resinas Sintéticas/química , Siloxanos/química , Factores de Tiempo
16.
J Appl Oral Sci ; 22(6): 496-501, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25591018

RESUMEN

Favorable results in the use of castor oil polyurethane (COP) as pulp capping, membrane material, sealer, mouthwash and in bone repair, associated with the fact that Ricinus communis is not derived from petroleum and it is abundant in Brazil, encourage researches in the development of luting agents. Objectives This study compared the flexural strength (FS) of a castor oil-containing dental luting agent with a weight percentage of 10% (wt%) of calcium carbonate (COP10) with RelyX ARC (RX) after mechanical cycling (MC) and distilled water storage. Material and Methods Sixty-four specimens (25x2x2 mm) were fabricated and divided into two groups, COP10 and RX (control). Each group was divided into 4 subgroups (n=8) according to the storage time, 24 hours (24 h) or 60 days (60 d), and the performance (MC+FS) or not (only FS) of the mechanical cycling test. The FS (10 kN; 0.5 mm/min) and MC tests (10,000 cycles, 5 Hz, 0.5 mm/min) were carried out using an MTS-810 machine. The data were analyzed using ANOVA (α=0.05). Results The obtained FS (MPa) values were: COP10 24h- 19.04±2.41; COP10 60d- 17.92±3.54; RX 24h- 75.19±3.43; RX 60d- 88.77±6.89. All the RX specimens submitted to MC fractured, while the values for COP10 after MC were as follows: COP10 24h- 17.90±1.87 and COP10 60d- 18.60±1.60. Conclusions A castor oil-containing dental luting agent with a weight percentage of 10% (wt%) of calcium carbonate is resistant to mechanical cycling without decreases in flexural strength. However, mean COP10 showed only about 25% of the RelyX ARC mean flexural strength.


Asunto(s)
Bisfenol A Glicidil Metacrilato/química , Carbonato de Calcio/química , Aceite de Ricino/química , Cementos Dentales/química , Polietilenglicoles/química , Ácidos Polimetacrílicos/química , Poliuretanos/química , Análisis de Varianza , Análisis del Estrés Dental , Inmersión , Ensayo de Materiales , Docilidad , Valores de Referencia , Estrés Mecánico , Factores de Tiempo , Agua/química
17.
ISRN Dent ; 2012: 704246, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23008777

RESUMEN

Objective. The aim of this study was to evaluate the radiopacity of two conventional cements (Zinc Cement and Ketac Cem Easymix), one resin-modified glass ionomer cement (RelyX Luting 2) and six resin cements (Multilink, Bistite II DC, RelyX ARC, Fill Magic Dual Cement, Enforce and Panavia F) by digitization of images. Methods. Five disc-shaped specimens (10 × 1.0 mm) were made for each material, according to ISO 4049. After setting of the cements, radiographs were made using occlusal films and a graduated aluminum stepwedge varying from 1.0 to 16 mm in thickness. The radiographs were digitized, and the radiopacity of the cements was compared with the aluminum stepwedge using the software VIXWIN-2000. Data (mmAl) were submitted to one-way ANOVA and Tukey's test (α = 0.05). Results. The Zinc Cement was the most radiopaque material tested (P < 0.05). The resin cements presented higher radiopacity (P < 0.05) than the conventional (Ketac Cem Easymix) or resin-modified glass ionomer (RelyX Luting 2) cements, except for the Fill Magic Dual Cement and Enforce. The Multilink presented the highest radiopacity (P < 0.05) among the resin cements. Conclusion. The glass ionomer-based cements (Ketac Cem Easymix and RelyX Luting 2) and the resin cements (Fill Magic Dual Cement and Enforce) showed lower radiopacity values than the minimum recommended by the ISO standard.

18.
Int J Oral Maxillofac Implants ; 27(3): 544-50, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22616047

RESUMEN

PURPOSE: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. MATERIALS AND METHODS: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. RESULTS: The mean values (± standard deviations) for the abutment/framework interface gaps were: master cast, 32 ± 2 Μm; tapered metal, 44 ± 10 Μm; splinted metal, 69 ± 28 Μm; tapered plastic, 164 ± 58 Μm; splinted plastic, 128 ± 47 Μm. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. CONCLUSIONS: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast.


Asunto(s)
Técnica de Impresión Dental/instrumentación , Análisis de Varianza , Implantes Dentales , Materiales de Impresión Dental , Precisión de la Medición Dimensional , Humanos , Arcada Edéntula , Mandíbula , Metales , Modelos Dentales , Plásticos , Polivinilos , Siloxanos , Estadísticas no Paramétricas
19.
J Appl Oral Sci ; 20(1): 16-20, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22437672

RESUMEN

UNLABELLED: The need to develop new dental luting agents in order to improve the success of treatments has greatly motivated research. OBJECTIVE: The aim of this study was to evaluate the diametral tensile strength (DTS) and film thickness (FT) of an experimental dental luting agent derived from castor oil (COP) with or without addition of different quantities of filler (calcium carbonate - CaCO3). MATERIAL AND METHODS: Eighty specimens were manufactured (DTS N=40; FT N=40) and divided into 4 groups: Pure COP; COP 10%; COP 50% and zinc phosphate (control). The cements were mixed according to the manufacturers' recommendations and submitted to the tests. The DTS test was performed in the MTS 810 testing machine (10 KN, 0.5 mm/min). For FT test, the cements were sandwiched between two glass plates (2 cm²) and a load of 15 kg was applied vertically on the top of the specimen for 10 min. The data were analyzed by means of one-way ANOVA and Tukey's test (α=0.05). RESULTS: The values of DTS (MPa) were: Pure COP- 10.94 ± 1.30; COP 10%- 30.06 ± 0.64; COP 50%- 29.87 ± 0.27; zinc phosphate- 4.88 ± 0.96. The values of FT (µm) were: Pure COP- 31.09 ± 3.16; COP 10%- 17.05 ± 4.83; COP 50%- 13.03 ± 4.83; Zinc Phosphate- 20.00 ± 0.12. One-way ANOVA showed statistically significant differences among the groups (DTS - p=1.01E-40; FT - p=2.4E-10). CONCLUSION: The experimental dental luting agent with 50% of filler showed the best diametral tensile strength and film thickness.


Asunto(s)
Aceite de Ricino/química , Cementos Dentales/química , Análisis de Varianza , Carbonato de Calcio/química , Materiales Dentales , Análisis del Estrés Dental , Humanos , Ensayo de Materiales , Resistencia a la Tracción
20.
Full dent. sci ; 3(10): 193-197, jan.-mar. 2012. ilus
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-642920

RESUMEN

Devido à melhoria nas propriedades das resinascompostas indiretas, principalmente quandoassociadas com fibras de reforço, esse materialtornou-se mais uma alternativa para os procedimentosreabilitadores. Um paciente, 57 anos,compareceu à Clínica de Prótese da Faculdadede Odontologia de Araraquara, queixando-seda ausência do primeiro molar superior direito.Após exame clínico, verificou-se diminuiçãono periodonto de suporte do segundo molarsuperior direito, restaurado com amálgama esegundo pré-molar superior direito reabilitadoinsatisfatoriamente. De acordo com as condiçõesclínicas e os anseios estéticos do paciente,foi confeccionada uma prótese parcial fixa de 3elementos, utilizando resina composta indiretacom fibras de reforço. O paciente demonstrouseplenamente satisfeito com o resultado estéticoe funcional obtido. O caso encontra-se emproservação há 60 meses.


Due to mechanical and aesthetic improvementproperties, continuous fiber-reinforcedcomposites have been developed to replacethe metal framework in fixed partial denturesbecoming an interesting alternative toconventional treatments. A male patient, 57years old, attended at Fixed Partial DentureClinic of Araraquara Dental School - UNESP,complaining about upper right first molar absence.After clinical examination, it was observed:upper right second molar with amalgamrestoration and periodontal bone reductionand upper right second premolar unsatisfactorytreated. Following the clinical conditionsand the patient expectations, it was decidedto use a fiber-reinforced composite resin tomake a three-element fixed bridge. The patientshowed full satisfaction with the aestheticand functional results. The case has beenfollowed up for 60 months.


Asunto(s)
Humanos , Persona de Mediana Edad , Estética Dental , Dentadura Parcial Fija , Rehabilitación Bucal/instrumentación , Resinas Compuestas/química , Materiales Dentales/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...